ProBee-ZU10 Firmware Version PTv1.5 Release Notes February 22, 2012 Copyright (c) 2010 ~ 2012, Sena Technologies, Inc. INTRODUCTION ============= These release notes describe new features added and bugs fixed since the firmware PTv1.4 release. ENHANCEMENTS ============== + Changed the factory default value of ATS11 and AT+FLOWCTRL. BUG FIXES ========= - Fixed the problem with AT+AI on none and S/W flow control mode. KNOWN BUGS =========== * None. REVISION HISTORY ================ PTv1.4 September 29, 2011 + Added AT+RSSI Command. + Changed the range of RSSI value at the AT+ESCAN result. PTv1.3 August 22, 2011 + Increased the number of child nodes a coordinator or a router from 5 to 10. + Changed the response for AT+DSCAN to send child node information with the 16-bit Node ID from the 32-bit IEEE address. + Added the feature to display all the non-printable data in command mode by encoding them with printable format. + Added the feature always to permit joining by changing the default value of Permit Joining Timeout(ATS22) from 60 to 255. - Fixed the problem in AT+UPDATEKEY command. - Fixed the problem in losing data on receiving chunk data in command mode. PTv1.2 November 5, 2010 - Fixed the problem in repairing the source route automatically. PTv1.1 October 6, 2010 + Initial Release CONTACTS ========= Sena Technologies Inc. 210 Yangjae-dong, Seocho-gu Seoul, Korea 137-130 url: http://www.sena.com email: info@sena.com phone: +82-2-573-7772 fax: +82-2-573-7710 Technical support: email: support@sena.com phone: +82-2-576-7362